See General Information for Roofing Systems

PRO-TECH PRODUCTS INCR16029
3003 N 73RD ST
SCOTTSDALE, AZ 85251 USA

North Carolina Foam Ind. "591 Series" urethane foam insulation may be used as an alternate to "Pro-Tech Urethane Foam" in any of the non-combustible systems listed below.

Any of the systems listed below may be covered with a field mixed coating composed of "Pro-Tech Products Dry Mix" (40 lbs), Rohm & Haas MC-76 (1/2 gal), Rhone-Poulenc Colloid 622 (3/4 oz), 4-1/2 gal. Water applied per 100 sq ft.

Young Builders Roofing "DuraGard Roof Mix" may be used in lieu of "Pro-Tech Dry Mix II" in any of the following roofing systems.

SPRAY APPLIED FOAM AND COATING SYSTEMS

Class A

1. Deck: NC Incline: 1
Foam: — "Pro-Tech Urethane Foam" insulation, min 1 in. thick.
Base coat: — EC-100, at 1-1/2 gal/sq.
Top coat: — EC-100, at 1-1/2 gal/sq.
2. Deck: NC Incline: 1-1/2
Foam: — "Pro-Tech Urethane Foam" insulation, 1 in. thick.
Base coat: — EC-100, at 1-1/2 gal/sq.
Top coat: — EC-100, at 1-1/2 gal/sq.
3. Deck: NC Incline: 1/2
Foam: — "Pro-Tech Urethane Foam" or Polythane Systems SH-200-25 insulation, min 1 in. thick.
Base coat: — EC-100, at 1-1/2 gal/sq.
Top coat: — EC-100, at 1-1/2 gal/sq.
4. Deck: C-15/32 Incline: 1/4
Foam: — "Pro-Tech Products Urethane Foam", or Polythane Systems SH-200-25 insulation, min 2 in. thick.
Coating: — Two or three coats EC-100, at 1-1/4 gal/sq/coat with "Pro-Tech Granules" (not UL Classified) at 64 lb/sq imbedded into one of the wet coats.
Surfacing: — Mixture of "Pro-Tech Products Dry Mix" (40 lbs), Rohm & Haas MC-76 (1/2 gal), Rhone-Poulenc Colloid 622 (3/4 oz) and water (4-1/2 gal.) spray applied per 100 sq ft.
5. Deck: C-15/32 Incline: 1/2 Impact: 1
Tape: — All joints in deck taped with one layer of 2 mil thick aluminum backed 2 in. wide tape.
Foam: — "Pro-Tech Urethane Foam" insulation only, min 1 in. thick.
Coating: — Two or three coats EC-100, at 1-1/4 gal/sq/coat with "Pro-Tech Granules" (not UL Classified) at 64 lb/sq imbedded into one of the wet coats.
Surfacing: — Mixture of "Pro-Tech Dry Mix II" (40 lbs), Rohm & Haas MC-76 (1/2 gal), Rhone-Poulenc Colloid 622 (3/4 oz) and water at (3-1/2 to 4-1/2 gal.) spray applied per 100 sq ft.
6. Deck: NC Incline: Unlimited Impact: 1
Foam: — "Pro-Tech Urethane Foam" insulation only, min 1 in. thick.
Coating: — Two or three coats EC-100, at 1-1/4 gal/sq/coat with "Pro-Tech Granules" (not UL Classified) at 64 lb/sq imbedded into one of the wet coats.
Surfacing: — Mixture of "Pro-Tech Dry Mix II" (40 lbs), Rohm & Haas MC-76 (1/2 gal), Rhone-Poulenc Colloid 622 (3/4 oz) and water at (3-1/2 to 4-1/2 gal) spray applied per 100 sq ft.
7. Deck: NC Incline: Unlimited
Insulation: — North Carolina Foam "10-001", any thickness
Base/Top Coat: — "EC-100" at 1-1/2 gal/sq (two applications) plus Granules (50 lbs/sq) imbedded into one of the wet coats.
Surfacing: — Mixture of "Pro-Tech Dry Mix II" (40 lbs), Rohm & Haas MC-76 (1/2 gal), Rhone-Poulenc Colloid 622 (3/4 oz) and water at (3-1/2 to 4-1/2 gal.) spray applied per 100 sq ft.
8. Deck: 15/32 Incline: 1/2
Tape: — All joints in deck taped with one layer of 2 mil thick aluminum backed 2 in. wide tape.
Insulation: — North Carolina Foam "10-001", 1 in. thickness.
Base/Top Coat: — "EC-100" at 1-1/2 gal/sq (two applications) plus Granules(50 lbs/sq) imbedded into one of the wet coats.
Surfacing: — Mixture of "Pro-Tech Dry Mix II" (40 lbs), Rohm & Haas MC-76 (1/2 gal), Rhone-Poulenc Colloid 622 (3/4 oz) and water at (3-1/2 to 4-1/2 gal.) spray applied per 100 sq ft.
9. Deck: NC Incline: 3
Insulation: — North Carolina Foam "10-001", any thickness.
Base/Top Coat: — "EC-100"or "Pro-White" at 1-1/2 gal/sq (two applications) plus Granules(50 lbs/sq)imbedded into one of the wet coats.
10. Deck: NC Incline: 1
Insulation: — North Carolina Foam "10-001", any thickness.
Base/Top Coat: — "EC-100"or "Pro-White" at 1-1/2 gal/sq (two applications).

Class B

1. Deck: C-15/32 Incline: 1/2
Foam: — "Pro-Tech Urethane Foam" insulation, min 1 in. thick.
Base coat: — EC-100, at 1-1/2 gal/sq followed immediately with "Pro-Tech Granules" (not UL Classified) at 50 lb/sq imbedded in wet coating.
Top coat: — EC-100, at 1-1/2 gal/sq.
2. Deck: C-15/32 Incline: 1/2
Foam: — "Pro-Tech Urethane Foam" or Polythane systems SH-200-25 insulation, min 2 in. thick.
Base coat: — EC-100, at 1-1/2 gal/sq followed immediately with "Pro-Tech Granules" (not UL Classified) at 50 lb/sq imbedded in wet coating.
Top coat: — EC-100, at 1-1/2 gal/sq.
3. Deck: 15/32 Incline: 1/2
Insulation: — North Carolina Foam "10-001", 1 in. thickness.
Base/Top Coat: — "Pro-White" at 1-1/2 gal/sq (two applications)plus Granules(50 lbs/sq)imbedded into one of the wet coats.
4. Deck: 15/32 Incline: 1/2
Insulation: — North Carolina Foam "10-001", 1 in. thickness.
Base/Top Coat: — "EC-100" at 1-1/2 gal/sq (two applications)

MAINTENANCE AND REPAIR SYSTEMS

Class A, B or C

1. Deck: NC Incline: 1
Existing Roof System: — Class A, B or C roofing system to retain its present classification when covered with:
Foam: — "Pro-Tech Urethane Foam" insulation, min 1 in. thick.
Base coat: — EC-100, at 1-1/2 gal/sq.
Top coat: — EC-100, at 1-1/2 gal/sq.
2. Deck: NC Incline: 1-1/2
Existing Roof System: — Class A, B or C roofing system to retain its present classification when covered with:
Foam: — "Pro-Tech Urethane Foam" insulation, 1 in. thick.
Base coat: — EC-100, at 1-1/2 gal/sq.
Top coat: — EC-100, at 1-1/2 gal/sq.
3. Deck: C-15/32 Incline: 1/2
Existing Roof System: — Class A, B or C roofing system to retain its present classification when covered with:
Foam: — "Pro-Tech Urethane Foam" insulation, min 1 in. thick.
Base coat: — EC-100, at 1-1/2 gal/sq followed immediately with "Pro-Tech Granules" (not UL Classified) at 50 lb/sq imbedded in wet coating.
Top coat: — EC-100, at 1-1/2 gal/sq.
4. Deck: NC Incline: 1/2
Existing Roof System: — Class A, B or C roofing system to retain its present classification when covered with:
Foam: — "Pro-Tech Urethane Foam" or Polythane Systems SH-200-25 insulation, min 1 in. thick.
Base coat: — EC-100, at 1-1/2 gal/sq.
Top coat: — EC-100, at 1-1/2 gal/sq.
5. Deck: C-15/32 Incline: 1/2
Existing Roof System: — Class A, B or C roofing system to retain its present classification when covered with:
Foam: — "Pro-Tech Urethane Foam" or Polythane Systems SH-200-25 insulation, min 2 in. thick.
Base coat: — EC-100, at 1-1/2 gal/sq followed immediately with "Pro-Tech Granules" (not UL Classified) at 50 lb/sq imbedded in wet coating.
Top coat: — EC-100, at 1-1/2 gal/sq.

Class A

1. Deck: C-15/32 Incline: 1/4
Existing Roof System: — Class A, B or C roofing system covered with:
Foam: — "Pro-Tech Products Urethane Foam"or Polythane Systems SH-200-25 insulation, min 2 in. thick.
Coating: — Two or three coats EC-100, at 1-1/4 gal/sq/coat with "Pro-Tech Granules" (not UL Classified) at 64 lb/sq imbedded into one of the wet coats.
Surfacing: — Mixture of "Pro-Tech Products Dry Mix" (40 lbs), Rohm & Haas MC-76 (1/2 gal), Rhone-Poulenc Colloid 622 (3/4 oz) and water (4-1/2 gal.) spray applied per 100 sq ft.
2. Deck: C-15/32 Incline: 1/2 Impact: 1
Existing Roof System: — Class A, B or C roofing system covered with:
Foam: — "Pro-Tech Urethane Foam" insulation only, min 1 in. thick.
Coating: — Two or three coats EC-100, at 1-1/4 gal/sq/coat with " Pro-Tech Granules" (not UL Classified) at 64 lb/sq imbedded into one of the wet coats.
Surfacing: — Mixture of "Pro-Tech Dry Mix II" (40 lbs), Rohm & Haas MC-76 (1/2 gal), Rhone-Poulenc Colloid 622 (3/4 oz) and water at (3-1/2 to 4-1/2 gal.) spray applied per 100 sq ft.
3. Deck: NC Incline: Unlimited Impact: 1
Existing Roof System: — Class A, B or C roofing system covered with:
Foam: — "Pro-Tech Urethane Foam" insulation only, min 1 in. thick.
Coating: — Two or three coats EC-100, at 1-1/4 gal/sq/coat with "Pro-Tech Granules" (not UL Classified) at 64 lb/sq imbedded into one of the wet coats.
Surfacing: — Mixture of "Pro-Tech Dry Mix" (40 lbs), Rohm & Haas MC-76 (1/2 gal), Rhone-Poulenc Colloid 622 (3/4 oz) and water at (3-1/2 to 4-1/2 gal.) spray applied per 100 sq ft.
Last Updated on 2006-07-10

Questions?

Notice of Disclaimer

Page Top

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2006 Underwriters Laboratories Inc.®"